title: Product Passport
weight: 1
---

import Alert from '@/components/docs/Alert.astro';

![AIIoTU8](./images/aiiotu8.jpg)

## General Information

### Purpose

The VADTel-AIIoTU8 unit is intended for remote telemetry from utility meters including gas volume correctors, heat calculators, and water meters. It transmits data to a centralized server for collection, analysis, and long-term storage using GSM/GPRS networks operating at 900/1800 MHz frequencies. Includes integrated Ex ib IS barrier RS-485 interface for intrinsically safe connections (optional for EX version).

#### Key Advantages

- Universal compatibility with major brands of correctors and calculators
- Fully autonomous operation using an internal high-capacity battery
- Remote firmware update via server command — supporting protocol evolution without field technician visits
- Auxiliary power output for RS-485 interface and attached devices
- Local analysis of emergency events with real-time reporting to server or SMS notifications

#### Functional Description

- Scheduled polling of meters with onboard storage of collected data
- Adaptive transmission to the server via GPRS — based on schedule or emergency triggers
- Emergency event detection and alerts sent via SMS to configured numbers
- Multi-protocol support for integration with a range of meter types
- Real-time and historical data access via server dashboard
- Remote configuration including polling intervals via SMS

### Application

- Commercial measurement and billing of gas, thermal energy, and water
- Municipal and industrial telemetry systems
- Utility infrastructure in smart cities
- Automated Metering Infrastructure (AMI) solutions

### Compliance with EU Directives

The VADTel-AIIoTU8 complies with the following EU directives:

- **EMC Directive 2014/30/EU** (EN 55032:2015, EN 55035:2017) — verified by SIM800C_EMC Test Report_2024.
- **EMC Directive 2014/30/EU** (EN IEC 61000-6-1:2019, EN IEC 61000-6-3:2021, EN IEC 61000-3-2:2019/A1:2021, EN 61000-3-3:2013/A2:2021/AC:2022-01) — verified by PKCELL_LP_CE-EMC_Certificate_2024
- **RED Directive 2014/53/EU** (Radio Equipment Directive) — certified by SIM800C_CE(RED) Certificate_2024.
- **RoHS Directive 2011/65/EU** — verified by SIM800C_ROHS_Test Report_2019.
- **WEEE Directive 2012/19/EU** (Waste Electrical and Electronic Equipment).
- **GDPR** (Data transmission security and privacy).
- **SAR/MPE Requirements** (EN 62311:2020) — verified by SIM800C_MPE Test Report_2024.

### Environmental Conditions

- Operating temperature: **−40 °C to +60 °C**.
- Humidity: **up to 98% at +35°C** (non-condensing).
- Ingress Protection: **IP54** (IEC 60529).
- Impact Resistance: **IK07** (EN 62262).

### Power Supply

- Built-in battery: **3.7 V, Li-ion, 8,000 mAh**.
- Operating voltage: **3.4–4.2 V**.
- Power consumption:
  - Transmission mode: **≤600 mA**.
  - Standby mode: **≤0.003 mA**.

<Alert type="warning">
  - This device itself is not ATEX certified equipment and shall not be installed in Zone 0, 1, or 2
  areas. - Installation in explosive environments is prohibited. - However, the device integrates an
  intrinsically safe (Ex ib) RS-485 interface for connection to certified Zone 1 equipment (e.g.
  Elster EK). The device itself shall be installed outside hazardous areas (optional for EX
  version).
</Alert>

## Identification Information

### Serial Number

Each device is assigned a unique serial number. Example format: VAD-1234567890.

### Manufacture Date

The production date is indicated on the device label in the format YYYY-MM-DD (e.g., 2025-04-15).

### Document Version

- Passport version: 1.1
- Passport release date: 2024-04-21

### Released By

- Authorized Person: Markus Schmidt
- Position: Head of Quality Assurance
- Signature: ************\_************
- Date of Release: ********\_\_\_********

## Technical Specifications

### Key Parameters

| Parameter                | Value                                                                                                                                           |
| ------------------------ | ----------------------------------------------------------------------------------------------------------------------------------------------- |
| Frequency Bands          | GSM: 850/900/1800/1900 MHz <br /> LTE-M: B1/B3/B8/B20                                                                                           |
| Transmission Power (Max) | 2W (850/900 MHz), 1W (1800/1900 MHz)                                                                                                            |
| Communication Protocols  | MQTT, HTTP/HTTPS, TCP/IP                                                                                                                        |
| Security Features        | Encrypted communication protocols (HTTPS, MQTT-TLS), authentication and access control, firmware update capability to mitigate vulnerabilities. |
| Communication Module     | SIM800C (CE-RED, RoHS, EMC, MPE)                                                                                                                |
| Dimensions (L×W×H)       | 161×101×60 mm                                                                                                                                   |
| Weight                   | ≤1 kg                                                                                                                                           |
| Service Life             | ≥5(10) years                                                                                                                                    |
| Humidity                 | Up to 98% (+35°C)                                                                                                                               |
| Protection               | IP54, IK07                                                                                                                                      |

### Intrinsically Safe Interface RS-485 Entity Parameters (optional for EX version)

| Parameter                       | Value     | Comment |
| ------------------------------- | --------- | ------- |
| Type of protection              | Ex ib IIC | —       |
| Uo (max output voltage allowed) | 10.5      | V       |
| Io (max output current allowed) | 40        | mA      |
| Po (max output power allowed)   | 0.5       | W       |
| Co (capacitance)                | < 0.4     | μF      |
| Lo (inductance)                 | < 1       | mH      |

### Warranty

- Warranty period: **24 months** from the date of purchase.
- The warranty becomes void if installation rules are violated or if the device is tampered with.

## Package Contents

| Item                | Quantity               |
| ------------------- | ---------------------- |
| VADTel-AIIoTU8 Unit | 1                      |
| Product Passport    | 1                      |
| Interface Cable     | 5 m                    |
| Antenna             | 1                      |
| CE Certificate      | 1 (electronic version) |

<Alert type="note">
  The SIM card (eSIM) is pre-activated and linked to the VAD IIoT Ecosystem.
</Alert>

## Installation & Operation

### Installation

- Installation must be performed by certified specialists.
- Normally, no configuration of the module is necessary.
- Installation requirements:
  - Protect from direct sunlight.
  - Minimum distance from metal structures: 3 cm.

### Maintenance

- Annual inspection:
  - Check for housing and seal integrity.
  - Clean with a dry, soft cloth.

### Connection diagram

The connection diagram for the unit to the Elster EK series corrector is shown in the figure below.

```mermaid
%%{init: {'flowchart': {'curve':'linear','nodeSpacing':18,'rankSpacing':130,'padding':26,'subGraphTitleMargin':{'top':10,'bottom':18}}}}%%
flowchart LR
  subgraph DEV1["«AIIoTU8»"]
    direction TB
    J8_1["J8 · 1 · T+"]
    J8_2["J8 · 2 · T-"]
    J2_1["J2 · 1 · R+"]
    J2_2["J2 · 2 · R-"]
    J2_3["J2 · 3 · +U"]
    J2_4["J2 · 4 · -U"]
  end

  JP(( )):::dot
  JN(( )):::dot

  subgraph DEV2["«EK2xx»"]
    direction TB
    EK_T2["2 · T+"]
    EK_T1["1 · T-"]
    EK_R4["4 · R+"]
    EK_R3["3 · R-"]
    EK_Ri["5 · Ri"]
    EK_GND["6 · GND"]
    EK_Up["1 · +Uext"]
    EK_Un["2 · -Uext"]
  end

  SHLD["Cable shield"]
  ERTH["⏚ PE"]

  J8_1 --- EK_T2
  J8_2 -.- EK_T1
  J2_1 --- EK_R4
  J2_2 -.- EK_R3
  J2_3 --- JP
  JP --- EK_Ri
  JP --- EK_Up
  J2_4 -.- JN
  JN -.- EK_GND
  JN -.- EK_Un
  SHLD -..- ERTH

  linkStyle 0 stroke:#22b14c,stroke-width:2.5px
  linkStyle 1 stroke:#22b14c,stroke-width:2.5px,stroke-dasharray:6
  linkStyle 2 stroke:#00aeef,stroke-width:2.5px
  linkStyle 3 stroke:#00aeef,stroke-width:2.5px,stroke-dasharray:6
  linkStyle 4 stroke-width:2.5px
  linkStyle 5 stroke:#f15a24,stroke-width:2.5px
  linkStyle 6 stroke:#a06a3a,stroke-width:2.5px
  linkStyle 7 stroke-width:2.5px,stroke-dasharray:6
  linkStyle 8 stroke:#f15a24,stroke-width:2.5px,stroke-dasharray:6
  linkStyle 9 stroke:#a06a3a,stroke-width:2.5px,stroke-dasharray:6
  linkStyle 10 stroke:#888888,stroke-width:1.5px,stroke-dasharray:3

  classDef dot fill:#888888,stroke:#888888;
```

Programming interfaces of Elster "EK" series correctors for work with VADTel-AIIoTU8:

| Designation              | AD    | Address | Value | Description                        |
| ------------------------ | ----- | ------- | ----- | ---------------------------------- |
| Mode, Interface 2        | Md.S2 | 2:705   | 5     | Without control lines              |
| Data format, Interface 2 | DF.S2 | 2:707   | 2     | 8 data bits, no parity, 1 stop bit |
| Baud rate, Interface 2   | Bd.S2 | 2:708   | 6     | 19200                              |
| Type, Interface 2        | TypS2 | 2:70A   | 2     | RS485                              |

## Safety & Disposal

Ensure correct connection to certified intrinsically safe equipment. No modifications to the internal IS barrier are permitted without conformity assessment (optional for EX version).

<Alert type="warning">
  - Do not dismantle the device — risk of battery damage! - Dispose of the device according to the
  **WEEE Directive**: deliver to a specialized recycling center.
</Alert>

### RoHS Compliance

The device does not contain:

- Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent Chromium (CrVI).
- Polybrominated Biphenyls (PBBs), Polybrominated Diphenyl Ethers (PBDEs).
- Phthalates (DEHP, BBP, DBP, DIBP) in concentrations exceeding 0.1%.

### Contacts

- Manufacturer: V.A.D. Technical Engineering and Investment s.r.o.
- Address: Konvetna 6, 81 103 Bratislava, Slovakia.
- Phone: +421 910 411 379.
- Email: [inbox@vadsro.eu](mailto:inbox@vadsro.eu).
- Website: [https://vadsro.eu](https://vadsro.eu).

## Marking / Labeling

### CE Marking

Label includes:

- Device name (VADTel-AIIoTU8)
- Manufacturer name and address
- Serial number
- CE mark, WEEE

### VADTel-AIIoTU8 Label

![AIIoTU8 label](./images/label.png)

## Approvals / Certifications

The RS-485 interface complies with ATEX Directive 2014/34/EU for connection to Zone 1 devices under intrinsic safety protection concept (Ex ib) (optional for EX version).

Applicable standards: EN 60079-0, EN 60079-11, EN 60079-14, EN 61326-1.

## Revision History

| Version | Date    | Changes                                   |
| ------- | ------- | ----------------------------------------- |
| 1.0     | 01.2024 | Initial release.                          |
| 1.1     | 07.2024 | Added references to SIM800C certificates. |

## Additional Information

### SIM800C Certificates

- CE-RED (2024): Compliance with Directive 2014/53/EU (Radio Equipment).
- EMC (2024): Successfully passed electromagnetic compatibility tests.
- MPE (2024): SAR levels within limits (≤1.6 W/kg).
- RoHS (2019): Free of hazardous substances.

All certificates are available upon request through customer support.

## EU Declaration of Conformity

The manufacturer V.A.D. Technical Engineering and Investment s.r.o., Konvetna 6, 81103 Bratislava, Slovakia, hereby declares that the product:

Product name: **VADTel-AIIoTU8**
Description: Smart telemetry device with integrated RS-485 interface

is in conformity with the provisions of the following European Directives:

- **2014/30/EU** (EMC Directive)
- **2014/53/EU** (RED Directive)
- **2011/65/EU** (RoHS Directive)

and complies with the following harmonized standards\*:

- **EN 60079-0:2018** (Explosive atmospheres – General requirements)
- **EN 60079-11:2012** (Explosive atmospheres – Intrinsic safety "i")
- **EN 60079-14:2014** (Explosive atmospheres – Electrical installations design, selection and erection)
- **EN 61326-1:2013** (EMC requirements)

Important note: The device itself is not ATEX certified equipment and shall be installed outside hazardous areas. Only the RS-485 IS output complies with ATEX requirements for connection to certified Zone 1 (Category 2G, Ex ib IIC T4 Gb) equipment.

Place: Bratislava, Slovakia
Date: 1.04.2024

Signed by:
Markus Schmidt
Head of Quality Assurance
V.A.D. Technical Engineering and Investment s.r.o.

\* optional for EX version